home > product > AC-DC panel light power supply > BLH300W191
BLH300W191返回
characteristic:
Input voltage: AC-DC: AC100V-240V Frequency range: 47-63Hz
Input 2: DC-DC: DC24V-36V Input 3: DC: DC48V Battery pack
operating temperature: -20℃~+70℃ Storage temperature: -40 ℃~+85℃
Protection function: short circuit, overload, overvoltage, overtemperature Lightning strike (surge): 2KV/4KV
Altitude: 3000m Environmental protection directive: ROHS
Safety regulations: UL62368-1, EN62368-1, EN61347-2-13 , UL60950-1, EN61000-3-2 Warranty period: 3 years
|
model |
BLH600W260A |
BLH450W262 |
BLH300W191 |
BLH260W116 |
||||
|
Output voltage/current (Customizable voltage and current) |
AC/DCoutput (600W) |
DC/DCoutput (300W Max) |
AC/DCoutput (450W) |
DC/DCoutput (300W Max) |
AC/DCoutput (300W) |
DC/DCoutput (300W Max) |
AC/DCoutput (260W) |
DC/DCoutput (220W Max) |
|
24V 25A |
12V 25A |
24V 18.7A |
12V 25A |
24V 12.5A |
12V 25A |
24V 10.8A |
12V 18.3A |
|
|
36V 16.6A |
24V 12.5A |
36V 12.5A |
24V 12.5A |
36V 8.3A |
24V 12.5A |
36V 7.2A |
24V 9.1A |
|
|
48V 12.5A |
36V 8.3A |
48V 9.3A |
36V 8.3A |
48V 6.2A |
36V 8.3A |
48V 5.4A |
36V 4.5A |
|
|
52V 11.5A |
48V 6.2A |
52V 8.6A |
48V 6.2A |
52V 5.7A |
48V 6.2A |
52V 5A |
48V 4.2A |
|
|
60V 10A |
60V 5A |
63V 7.1A |
60V 5A |
63V 4.7A |
60V 5A |
63V 4.1A |
60V 3.4A |
|
|
Heat sink size (length*width*height mm) (Customizable size available) |
292*83*45 |
262*76.4*42 |
220*49*35 |
122*80*38 |
||||
|
Net weight (kg) |
|
|
|
|
||||
|
Input and output terminal specifications |
AC:7.62-3P DC:7.62-6P |
AC:7.62-3P DC:7.62-4P-2P |
AC:VH-5A-3P DC:VH-4P/VH-2P/XH-3P |
AC:VH-3A-2P DC:VH-4P/VH-2P |
||||
|
Product function description |
1.Input 1 or Input 2 or Input 3 work individually. 2. When input 1 and input 2 are powered on at the same time, use ADC to detect and give priority to input 1. 3. When input 1 and input 3 are used at the same time, the one with higher voltage will be used first. 4. When input 2 and input 3 are powered on at the same time, input 2 takes priority. 5. The battery port has a delay function, there is no spark when plugging or unplugging, and the battery consumes less than 100UA. 6. When input 1 is working, the voltage of the 48V battery pack port is 0V to prevent accidents caused by short circuit or touch. |
|||||||
|
Cooling method: 1.25CFMFan cooling 2.Natural air cooling (conduction heat dissipation at the bottom) |
1.600W 2.500W(derating) |
1.450W 2.350W(derating) |
1.300W 2.200W(derating) |
1.260W 2.200W(derating) |
||||
|
Efficiency (PF value)@25℃ |
93%(100V) 95%(220V) |
86%(100V) 88%(220V) |
91%(100V) 93%(220V) |
91%(100V) 93%(220V) |
||||
|
Power factor@25℃ |
100V>0.99PF220V>0.93PF |
100V>0.98PF 220V>0.94PF |
100V>0.99PF 220V>0.93PF |
100V>0.99PF 220V>0.93PF |
||||
|
Dielectric strength |
Input - output: 3KVac/10mA; input - case: 1.5KVac/10mA; output - case: 0.5KVdc/10mA, each test time is 1min |
|||||||
|
leakage current |
Input to ground ≤ 3.5mA; input to output ≤ 0.75mA (input 264Vac, frequency 63Hz) |
|||||||
|
Packaging |
Static bag + carton |
|||||||