home > product > AC/DC customized power supply > BLH200W100A
BLH200W100A返回
characteristic:
Input voltage: 90V-264VAC 127V-370VDC Frequency range: 47-63Hz
Operating temperature: -20℃~+70℃ Storage temperature: -40℃~+85℃
Protection function: short circuit, overload, overvoltage, overtemperature lightning strike ( Surge): 2KV/4KV
Altitude: 3000m Environmental protection directive: ROHS
Safety regulations: UL62368-1, EN62368-1, EN61347-2-13, UL60950-1, EN61000-3-2
Warranty period: 3 years
|
model |
BLH250W100 |
BLH200W126 |
BLH200W100A |
BLH150W80A |
|
Output voltage/current ( Voltage and current can be customized) |
24V 10.4A |
24V 8.3A |
24V 8.3A |
24V 6.2A |
|
36V 6.9A |
36V 5.5A |
36V 5.5A |
36V 4.1A |
|
|
48V 5.2A |
48V 4.1A |
48V 4.1A |
48V 3.1A |
|
|
52V 4.8A |
52V 3.8A |
52V 3.8A |
52V 2.8A |
|
|
63V 3.9A |
63V 3.1A |
63V 3.1A |
63V 2.3A |
|
|
Heat sink size (length*width*height mm) (size can be customized) |
100*61*35 |
126*126*40.3 |
100*50*38 |
80*60*30.8 |
|
Net weight (kg) |
|
|
|
|
|
Input and output terminal specifications |
AC: VH-3A-2P DC:VH-2P |
AC: Fence terminal 7.62-3P DC: pad |
AC:VH3.96-2P DC: blade terminal |
AC: VH3.96-3A-2P DC:VH3.96-2P |
|
Cooling method: 1.25CFM fan cooling 2. Natural air cooling (conduction heat dissipation at the bottom) |
1.250W 2.200W |
1.200W 2.200W |
1.200W 2.200W |
1.150W 2.150W |
|
Efficiency (PF value)@25℃ |
90%(100V) 91%(220V) |
90%(100V) 91%(220V) |
90%(100V) 91%(220V) |
90%(100V) 91%(220V) |
|
ripple noise |
≤240mV |
≤240mV |
≤240mV |
≤240mV |
|
Power factor@25℃ |
100V>0.99PF 220V>0.93PF |
100V>0.99PF 220V>0.93PF |
100V>0.99PF 220V>0.93PF |
100V>0.99PF 220V>0.93PF |
|
Peak power (>10S) |
105%-190% |
105%-190% |
105%-190% |
105%-190% |
|
Dielectric strength |
Input - output: 3KVac/10mA; input - case: 1.5KVac/10mA; output - case: 0.5KVdc/10mA, each test time is 1min |
|||
|
leakage current |
Input to ground ≤ 3.5mA; input to output ≤ 0.75mA (input 264Vac, frequency 63Hz) |
|||
|
Certification standards |
ETL.CE |
|||
|
Packaging |
Static bag + carton |
|||